Safety Data Sheet (SDS)
RRC-Batteries Rev.: Q Valid from: 12mar2024
EYE: If eye contact with contents of an open cell occurs, immediately flush the contaminated eye(s) with
water. Quickly transport victim to an emergency care facility.
Skin Contact: Immediately flush with water. If irritation or pain persists, seek medical attention.
Inhalation: Remove the patient from exposure into fresh air, seek medical attention.
Protection for First aiders: Do not enter corrosive vapour contaminated areas without a respirator or Self-
Contained Breathing Apparatus. Wear adequate personal protective equipment as indicated in
Section 8.
FIRST AID FACILITIES: Eye wash bottle, fountain, safety showers or at least a source of running water
are required in the area where the product is used.
4.2. Most important symptoms and effects, both acute and delayed
ACUTE: The contents of the battery are rated as corrosive. Ingestion of the electrolyte could lead to severe
gastrointestinal tract irritation with nausea, vomiting and potentially burns.
Inhalation of vapours may lead to severe irritation of the mouth and upper respiratory tract with a burning
sensation, pain, burns and inflammation in the nose and throat; there may also be coughing or difficulty
breathing. Eye contact may lead to severe eye irritation or in worst case scenario irreversible damage and
possible eye burns. Skin contact may lead to irritation and possible skin burns.
CHRONIC: Skin contact may aggravate/exacerbate existing skin conditions, such as dermatitis. Chronic
inhalation may lead to the same symptoms as listed for acute inhalation above.
4.3. Indication of any immediate medical attention and special treatment needed
ADVICE TO DOCTOR: Treat symptomatically if the person comes into contact with the corrosive electrolyte
liquid contents of a damaged battery.
SECTION 5: Firefighting measures
5.1. Extinguishing media
Cold water and dry powder in large amount are applicable.
Use metal fire extinction powder or dry sand if only few cells are involved.
5.2. Special hazards arising from the substance or mixture
May form hydrofluoric acid if electrolyte comes into contact with water.
In case of fire, the formation of the following flue gases cannot be excluded:
Hydrogen fluoride (HF), Carbon monoxide and carbon dioxide.
5.3. Advice for firefighters
Wear self-contained breathing apparatus and protective suit. If possible, remove cell(s) from fire fighting
area. If heated above 125°C, cell(s) can explode/vent. Cell is not flammable but internal organic material
will burn if the cell is incinerated.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
As an immediate precautionary measure, isolate spill or leak area for at least 25 meters (75 feet) in all
directions. Keep unauthorized personnel away. Stay upwind. Keep out of low areas. Ventilate closed areas
before entering. Wear adequate personal protective equipment as indicated in Section 8.
6.2. Environmental precautions
Absorb spilled material with non-reactive absorbent such as vermiculite, clay or earth. Prevent from into
migration soil, sewers and natural waterways – inform local authorities if this occurs.
6.3. Methods and material for containment and cleaning up
Evacuate spill area immediately and remove sources of ignition. Do NOT touch spilled material. Clean-up
personnel must be trained in the safe handling of this product. Spills may be absorbed on non-reactive
SDS_RRC Batteries_Q_2024-03-12.pdf Page 7 of 15